Fault 56: SVRV Out

InfoCenter Display:
Fault Description
The output current is too high from the TEC-5002 to the SVRV hydraulic lift/lower solenoid.
Note:
The SVRV solenoid is also referred to as the SV4 solenoid.
Circuit Description
The TEC controller uses inputs from various machine switches to determine when lift manifold solenoid valves
(SV1, SV2, SV3, and SVRV) are to be energized.
Conditions for Setting the Fault
There must be an electrical failure in the SVRV circuit to trigger this fault. It could be damaged wiring, a
shorted coil, or a malfunctioning TEC-5002 controller.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Test the wiring and coil resistance of SVRV
This Step measures the resistance of the wiring and the coil for SVRV.
Use a multimeter to test the resistance between the following pair of locations:
Location
Harness
1
Seat
2
_____FAULT
Returning the Machine to Service (page 22)
Connector
Pin
P75
2
Chassis ground
#56_____
SVRV
OUT
Clearing Faults from the InfoCenter (page
Wire
Expected
Color
Reading
Yellow/
Black
Approx. 8
ohms
201
21).
and follow the steps listed.