Pass
The 48 Vdc logic relay tests were good. Go to Step 3.
Fail
One or more of the 48 Vdc logic relay tests failed. Repair or replace the worn or damaged parts. Go
to
Returning the Machine to Service (page 22)
Step 3: Test the 48 Vdc power to the logic relay.
1.
Set the multimeter to measure Vdc and connect the probes to P32, pin 1 and J24 pin 1.
2.
Turn the ignition key to the O
3.
Turn the ignition key to the O
Location
Harness
1
Main
2
Main
Pass
The 48 Vdc logic relay power test was good. Go to
and follow the steps listed.
Fail
The 48 Vdc logic relay power test failed. Repair or replace the worn or damaged parts. Go to
Returning the Machine to Service (page 22)
Component Location and Electrical Connections
The 48 Vdc logic relay is mounted on a bracket behind the operator's seat on the left side of the machine.
position. You should measure 48 Vdc battery voltage.
N
position.
FF
Connector
Pin
P32
1
J24
1
(48 Vdc
Ground)
and follow the steps listed.
Wire
Expected
Color
Reading
Yellow
between
46.1 Vdc
and 54 Vdc
Black
Returning the Machine to Service (page 22)
and follow the steps listed.