1.
Press the Left button.
The Main Menu appears.
2.
Verify that the Faults menu item is selected, and then press the Right button.
The Faults screen appears.
3.
Press the Middle button to scroll down through the faults until Clear System Faults is selected.
4.
Press the Right button.
A confirmation screen appears.
5.
Press the Middle button to confirm clearing the InfoCenter fault log.
An "All faults cleared" message appears.
6.
Press the Left button as needed to return to the Main Menu screen.
Note:
Some faults clear when you turn the engine off and then start the engine. After the fault clears, you can
resume normal operation of the machine.
If a fault repeats each time you start the engine, conduct diagnostic troubleshooting of the affected system
and related components.

Preparing for Troubleshooting and/or Testing

CAUTION
Rings, watches, bracelets, necklaces, and other jewelry can cause an electrical shock or
become entangled with the machine.
Remove all jewelry, especially rings and watches, before doing any troubleshooting or testing.
Before performing troubleshooting and/or testing procedures on the machine, do the following steps:
1.
Park the machine on a level surface.
2.
Ensure that the traction pedal is in the N
3.
Shut off and lower the cutting units. Wait for all the movement to stop.
4.
Engage the parking brake.
5.
Move the engine speed switch to the L
6.
Shut off the engine and remove the key from the ignition switch.
CAUTION
Performing continuity testing on electrical components with the 12 Vdc and/or 48 Vdc
power connected can lead to severe electrical shock.
Disconnect power from the machine before testing electrical components.
7.
Disconnect the 12 Vdc battery before servicing the machine, unless it is needed for troubleshooting or
testing. Refer to
8.
Before installing, removing, or working on the 48 Vdc system, isolate the components (e.g., cutting reel
motors, motor/generator, etc.) by unplugging the 48 Vdc battery disconnect. Refer to
Disconnecting the 48 Vdc Battery System (page
The machine is now ready for testing and diagnostic work to take place.

Returning the Machine to Service

Ensure optimum performance and continued safety by performing all steps in the following procedure after all
diagnostic, maintenance, and/or repair activities are complete:
1.
Remove all diagnostic equipment and tools that are attached to the machine for troubleshooting or repair.
OW
Connecting and Disconnecting the 12 Vdc Battery (page
position.
EUTRAL
I
position and wait for the engine to slow to low idle speed.
DLE
19).
22
17).
Connecting and

Advertisement