Toro Reelmaster 5010-H Diagnostic Manual page 232

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

2.
Raise and support the operator's seat and the hood.
3.
Separate system components from the 48 Vdc battery pack by unplugging the 48 Vdc battery disconnect.
Refer to
Connecting and Disconnecting the 48 Vdc Battery System (page
4.
Check the cutting unit and the cutting reel motor for any mechanical resistance. Refer to
to locate cutting unit 2.
1. Cutting unit 1, which includes cutting reel motor 1
2. Cutting unit 2, which includes cutting reel motor 2
3. Cutting unit 3, which includes cutting reel motor 3
5.
After making sure the reels are free of any unwanted material, run the machine to see if the fault repeats.
Pass
If the fault does not repeat, go to
listed.
Fail
If the fault repeats, go to Step 3.
Step 3: Check the bedknife adjustment of cutting unit 2 and inspect
the reel.
1.
Check for proper bedknife adjustment and the overall condition of the reel; adjust the bedknife if it is out
of alignment (see the applicable Cutting Unit Operator's Manual).
2.
When the bedknife is properly adjusted, run the machine to see if the fault repeats.
Pass
If the fault does not repeat, go to
listed.
Fail
If the fault repeats, go to Step 4.
Step 4: Swap cutting reel motors between cutting units.
All of the cutting reel motors are identical.
1.
Go to
Preparing for Troubleshooting and/or Testing (page 22)
Figure 130
4. Cutting unit 4, which includes cutting reel motor 4
5. Cutting unit 5, which includes cutting reel motor 5
Returning the Machine to Service (page 22)
Returning the Machine to Service (page 22)
232
19).
and follow the steps
and follow the steps
and follow the steps listed.
Figure 130
g032972