Toro Reelmaster 5010-H Diagnostic Manual page 273

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

Step 4: Swap cutting reel motors between cutting units.
All of the cutting reel motors are identical.
1.
Go to
Preparing for Troubleshooting and/or Testing (page 22)
2.
Unplug the 48 Vdc battery disconnect to prevent unexpected cutting unit operation. Refer to
and Disconnecting the 48 Vdc Battery System (page
3.
Swap cutting reel motor 5 with a cutting reel motor from a different cutting unit. You can obtain more
information on replacing the cutting reel motor in Chapter 5 of the 5010-H Service Manual.
4.
Plug in the 48 Vdc battery disconnect. Refer to
(page
19).
5.
Operate the machine.
The fault moves to the
new position.
The fault repeats at the
original position.
The fault stopped
repeating.
Step 5: Use Toro DIAG to program the replacement cutting reel motor.
1.
Remove the access panel from the outer cover of the control arm.
2.
Connect a PC with Toro DIAG software to the machine via a Toro DIAG Cable (Part No. 115-1944). Refer
to
Toro DIAG - Quick Start (page
3.
Use the Toro DIAG software to reprogram the machine in accordance with Toro DIAG User's Guide. The
replacement cutting reel motor is programmed during the reprogramming of the machine.
4.
Disconnect the Toro DIAG cable from the machine.
5.
Install the access panel onto the outer cover of the control arm.
6.
Go to
Returning the Machine to Service (page 22)
Step 6: Swap cutting units.
Note:
All 5 cutting units are not physically identical. You can swap only cutting unit 5 with cutting unit 1
or cutting unit 3.
1.
Go to
Preparing for Troubleshooting and/or Testing (page 22)
2.
Unplug the 48 Vdc battery disconnect to prevent unexpected cutting unit operation. Refer to
and Disconnecting the 48 Vdc Battery System (page
3.
Swap cutting unit 5 with cutting unit 1 or cutting unit 3.
4.
Plug in the 48 Vdc battery disconnect. Refer to
(page
19).
5.
Operate the machine.
Connecting and Disconnecting the 48 Vdc Battery System
If the fault follows the cutting reel motor to the new cutting unit, replace the
cutting reel motor. Go to Step 5.
If the fault repeats at the cutting unit 5 position, go to Step 6.
If the fault no longer repeats, note the position change of the cutting reel motor
in the maintenance records for the machine. Should the fault repeat in the
future, troubleshooting may be resumed where you left off. Go to
Machine to Service (page 22)
24).
Connecting and Disconnecting the 48 Vdc Battery System
and follow the steps listed.
19).
and follow the steps listed.
and follow the steps listed.
and follow the steps listed.
19).
273
Connecting
Returning the
Connecting

Advertisement

Table of Contents
loading

This manual is also suitable for:

03674

Table of Contents