Step 2: Remove the motor/generator assembly from the machine.
1. Operator's seat
2. Motor/generator connector P37
Remove the motor/generator assembly from the machine. Refer to Chapter 5 of the 5010-H Service Manual.
See
Figure
126.
Step 3: Remove the controller from the motor/generator.
Remove the controller from the motor/generator. Refer to Chapter 5 of the 5010-H Service Manual.
Step 4: Inspect the wiring between the motor/generator and the
controller.
The motor/generator and the controller each have cabling that connects to the other component. Inspect the
wiring between the controller and the motor/generator.
Pass
The wiring between the controller and the motor/generator passed inspection. Go to Step 5.
Fail
The wiring between the controller and the motor/generator did not pass inspection. Only repair
wiring that has worn insulation or a recessed connector pin. Replace all components that have
damaged, burned, or broken wiring. Go to
the steps listed.
Step 5: Install a replacement controller onto the motor/generator.
Refer to Chapter 5 of the 5010-H Service Manual and follow the steps listed.
Step 6: Install the motor/generator assembly.
Refer to Chapter 5 of the 5010-H Service Manual and follow the steps listed.
Figure 126
3. Motor/generator controller (mounted to motor/generator
assembly)