Toro Reelmaster 5010-H Diagnostic Manual page 424

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

1. Cutting unit 1, which includes cutting reel motor 1
2. Cutting unit 2, which includes cutting reel motor 2
3. Cutting unit 3, which includes cutting reel motor 3
2.
Go to
Preparing for Troubleshooting and/or Testing (page 22)
3.
Unplug the 48 Vdc battery disconnect to prevent unexpected cutting unit operation. Refer to
and Disconnecting the 48 Vdc Battery System (page
4.
Disconnect main harness connectors P44 and P45 from the cutting reel motor cable connectors mounted
on the traction unit.
5.
Inspect the 2 cutting reel motor cable connectors and the 2 main harness connectors for damage,
corrosion, debris, and proper alignment of the pins inside the connectors.
Pass
The wiring inspection passed. Go to Step 3.
Fail
One or more of the wiring inspections failed. Repair or replace any worn or damaged parts. Go to
Returning the Machine to Service (page 22)
Step 3: Measure 48 Vdc power in main harness connectors P44 and
P45.
Note:
Connector diagrams are available in Step 4.
1.
Verify that the engine is shut off.
2.
Disconnect main harness connectors P44 and P45 from the cutting reel motor cable connectors.
3.
Rotate the ignition key to the O
4.
Measure the voltage between pins 1 and 2 of connector P45. The reading should be 48 Vdc.
5.
Measure the voltage between P44 pin 1 and P45 pin 2. The reading should be 48 Vdc.
6.
Rotate the ignition key to the O
Pass
The voltage readings were good. Go to Step 5.
Fail
The voltage readings were not good. Go to Step 4.
Figure 165
4. Cutting unit 4, which includes cutting reel motor 4
5. Cutting unit 5, which includes cutting reel motor 5
19).
and follow the steps listed.
position.
N
position.
FF
424
and follow the steps listed.