Fault 64: M/G Temperature Sensor Failure
InfoCenter Display:
Fault Description
Temperature sensor failures were detected within the motor/generator controller.
Circuit Description
There are 3 separate temperature sensors located inside the motor/generator. They are:
•
Field effect transistor (FET) temperature
•
Motor temperature
•
Logic board temperature
Conditions for Setting the Fault
If the FET and motor temperature sensors fail, this fault is reported.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Remove the motor/generator assembly from the machine.
Remove the motor/generator assembly from the machine. Refer to Chapter 5 of the 5010-H Service Manual.