Toro Reelmaster 5010-H Diagnostic Manual page 310

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

1. 48V disconnect
2. Operator's seat
2.
Use a multimeter to measure the voltage of the 48V battery pack across the main contactor. The reading
should be 46 to 54 Vdc
1.
A.
If the voltage reads low, remove cutting unit 1 and both of the battery covers
the voltage across each of the 4 individual batteries.
Figure 144
(Figure
145).
Figure 145
3. Main contactor
310
g035727
g036085
(Figure
146). Measure