Fault 24: Joystick Broken - Toro Reelmaster 5010-H Diagnostic Manual

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

Fault 24: Joystick Broken

InfoCenter Display:
Fault Description
The TEC-5002 detected a "cutting unit raise" command and a "cutting unit lower" command at the same
time from the joystick.
Circuit Description
There are 2 microswitches for the joystick located on the control arm. The rear switch on the control is used to
lower (and engage) the cutting units and the front switch to raise (and disengage) them.
Conditions for Setting the Fault
There must be a joystick switch broken/shorted internally or damaged wiring to send both a "raise" and "lower"
command simultaneously.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Note:
To raise or lower the deck sections, the operator seat must be occupied. Also, to lower the cutting deck
sections, the traction speed has to be in the L
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Test the joystick switches.
1.
Go to
Preparing for Troubleshooting and/or Testing (page 22)
2.
Test the joystick switches according to the component testing procedure outlined in Chapter 5 of the
5010-H Service Manual
_____FAULT
Joystick
(mow) range.
OW
Returning the Machine to Service (page 22)
(Figure
55).
#24_____
BAD
Clearing Faults from the InfoCenter (page
and follow the steps listed.
81
21).
and follow the steps listed.