[Ea31] Transport Jam In Finisher - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

MJ-1101/1107
Check item
Transport sensor
Finisher controller PC board
Parts to be replaced
Transport sensor
Finisher controller PC board
MJ-1106/1108
Check item
Finisher
Transport sensor (S2)
Finisher control PC board
(FIN)
Parts to be replaced
Transport sensor (S2)
Finisher control PC board
(FIN)

[EA31] Transport jam in Finisher

Classification
Paper jam in finisher section
MJ-1033
Probable cause
Entrance path sensor (S1)
abnormality
Faulty cables and connectors
Finisher control PC board (FIN)
abnormality
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
ERROR CODE AND TROUBLESHOOTING
Measures
Sensor check(S2)
Connector check (CN22)
Harness check
Board check
Connector check (CN22)
Harness check
Remark
Measures
Check if there is any paper in the finisher or on the transport path of
the equipment and remove it if there is.
Sensor check
Connector check
Harness check
Board check
Connector check (CN6)
Harness check
Remark
Error content
Paper transport remaining jam in the Finisher:
Checking and measures
Measure the voltage on TP1 on the finisher control PC board (FIN). Then
check that the measured voltage is 1V or lower when not shielded and
within the range of 3.3V
5% when shielded. If the voltage does not fall
within the range mentioned, replace the sensor.
Check if the electrical continuity between the connector terminals is normal.
If electricity is not conducted, replace the connector. (Finisher control PC
board (FIN): CN1)
If the error still occurs after replacing the sensor and the connector,
exchange the finisher control PC board (FIN).
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved