Reproduction Ratio Adjustment Of The Primary Scanning Direction - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[B] Reproduction ratio adjustment of the primary scanning direction
<Procedure>
While pressing [0] and [5] simultaneously, turn the power ON  (Adjustment Mode)
(1)
(2)
Place a ruler on the original glass (along the direction from the rear to the front of the equipment).
(3)
Press [FAX] -> [START] to make a copy at the mode of A3 (LD), 100% and the lower drawer
(Refer to *).
(4)
Measure the distance A from 10 mm to 270 mm of the copied image of the ruler.
(5)
Check if the distance A is within the range of 260±0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode)  (Key in the code [4000])  [START]
 (Key in a value (acceptable values: 0 to 255))
 Press the [OK] or the [INTERRUPT] button (stored in memory).
 ("100% A" is displayed.)
* The larger the adjustment value is, the higher the reproduction ratio and the longer the
distance A become.
e-STUDIO206L/256/306/356/456/506: approx. 0.125 mm/step
e-STUDIO207L/257/307/357/457/507: approx. 0.15 mm/step
Copied image of the ruler
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Feeding direction
Fig.6-13
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
6 - 15