6.11 Adjustment of Developer Unit

6.11.1

Doctor-to-sleeve gap

Adjustment tool to use: Doctor-sleeve jig
<Procedure>
(1)
Perform the adjustment code "05-2390".
(2)
Take out the process unit from the equipment.
(3)
Take out the developer unit from the process unit.
(4)
Remove 2 screws and take off the developer
material cover and discharge the developer
material.
Notes:
Discharge the developer material from the
rear side, being careful not to let it be
scattered on the gear.
(5)
Turn the adjustment screw to widen the gap
so that the jig can be inserted in it.
(Turning the screw clockwise widens the
gap)
(6)
Insert the gauge with the thickness "0.45" of
the doctor sleeve jig into the gap between
the developer sleeve and doctor blade after
lifting up the toner scattering prevention
sheet.
Adjust the screws with the doctor blade to
push the doctor sleeve jig lightly.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Fig.6-55
Fig.6-56
Doctor sleeve jig
Toner scattering
prevention sheet
Fig.6-57
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507