Exposure Lamp - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

4.6.7

Exposure lamp

(1)
Take off the original glass.
 P. 4-45 "4.6.1 Original glass"
(2)
Rotate the drive pulley and move the
carriage-1 [1] so that the screw can be seen
[2].
(3)
Remove 1 screw [3].
(4)
Lift the exposure lamp unit [4] and rotate the
exposure lamp unit in the direction shown in
the figure on the right. Then disconnect 1
connector [5].
(5)
Take off the exposure lamp unit [4].
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-141
Fig. 4-142
Fig. 4-143
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
4 - 49
DISASSEMBLY AND REPLACEMENT
4

Hide quick links:

Advertisement

Table of Contents
loading