Tray-Up Sensor (S16/S19); Empty Sensor (S17/S20) - Toshiba e-STUDIO206L Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

4.9.3

Tray-up sensor (S16/S19)

(1)
Take off the drawer feeding unit
( P. 4-63 "4.9.2 Drawer feeding unit").
(2)
Disconnect the connector and release the 3
latches to take off the tray-up sensor.
4.9.4

Empty sensor (S17/S20)

(1)
Take off the drawer feeding unit
( P. 4-63 "4.9.2 Drawer feeding unit").
(2)
Remove 1 screw and then slide the guide
slightly.
(3)
Disconnect 1 connector and then take off the
upper/lower drawer empty sensor by
releasing 3 latches.
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
DISASSEMBLY AND REPLACEMENT
Fig. 4-180
Guide
Fig. 4-181
Empty sensor
Fig. 4-182
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
4 - 64
Tray-up sensor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents