6.12 Adjustment of Dogleg

Dogleg is the name given to an image which is deformed approx. 48 mm of the trailing edge of the
output paper.
Since adjustment has usually been performed when the equipment was manufactured, dogleg image
should not occur. However, if the following dogleg image A or B does happen to occur, the following
adjustment must be performed. An original with a line parallel to the feeding direction is used for the
adjustment.
Normal Image
Feeding
Direction
Fig.6-62
Dogleg Image A
Dogleg Image B
Feeding
Feeding
Direction
Direction
Approx. 48 mm of
Approx. 48 mm of
the trailing edge
the trailing edge
Fig.6-63
Fig.6-64
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved