Toshiba e-STUDIO206L Service Manual page 503

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO206L:
Table of Contents

Advertisement

[B] Punch waste full sensor output adjustment
(1)
Turn OFF the power of the equipment.
(2)
Take off the rear cover of the finisher.
(3)
Confirm that the punch waste case is installed correctly and also no punch waste exists in the
case.
(4)
Set the bits 1, 2 and 3 of the DIP switch [2] on the hole punch control PC board (HP) [1] to ON.
Then turn ON the power of the equipment while pressing the push button switch [3] on the hole
punch control PC board (HP) [1] and the digital keys [0] and [8] on the control panel of the
equipment.
(5)
Set the bits 1, 2, 3 and 4 of the DIP switch [2] as shown in the table below.
Target sensor
Punch waste full sensors
(6)
Sensor output is adjusted automatically by pressing the push button switch [3].
LEDs [4] on the hole punch control PC board (HP) [1] start blinking as the adjustment is started.
When the adjustment is completed, the LEDs [4] are lit.
(7)
Turn OFF all bits of the DIP switch [2].
(8)
Install the rear cover of the finisher.