4.5.6

Scan motor (M1)

(1)
Take off the rear cover.
 P. 4-3 "4.1.6 Rear cover"
(2)
Take off the upper rear cover.
 P. 4-4 "4.1.7 Upper rear cover"
(3)
Disconnect 1 connector.
(4)
Remove 2 screws and take off the scan
motor with the whole bracket.
Notes:
When installing the scan motor, use the belt
tension jig (spring). The procedure is as
follows.
1. Temporarily fix the screw A and B.
 P. 4-35 "Fig. 4-103 "
2. Hook the belt tension jig to the motor
bracket and the flame.
3. The scan motor is pulled by the belt
tension jig. Fix the screw A and then B at
the stopped position.
4. Remove the belt tension jig.
© 2011-2014 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-102
Fig. 4-103
Fig. 4-104
e-STUDIO206L/256/306/356/456/506 / 207L/257/307/357/457/507
4 - 35
Scan motor
A
B
Belt tension jig