Step 1 Log in to the ECC800-Pro WebUI as an administrator.
Step 2 Choose System Settings > System Parameters > Monitor IP and change the IP, subnet
mask, and default gateway information for the ECC800-Pro as planned.
Step 3 Click Submit.
Step 4 In the displayed Setting succeeded. Log in again. dialog box, click OK.
----End

8.1.11 How Do I Configure ECC800-Pro Alarm Parameters?

Context
Procedure
Step 1 Log in to the ECC800-Pro WebUI as an administrator.
Step 2 Choose System Settings > Alarm Parameters.
Step 3 On the Basic Alarm Parameters page, choose ECC800 from the Select a device type
drop-down list box, choose the ECC800 to be set from the Device name drop-down list box,
and then click Confirm.
Step 4 Set Enable Alarm to Enable or Disable for Operation log full as required. Set Severity to
Critical, Major, Minor, or Warning as required.
Step 5 Enter the Alarm Linkage page. Select Device Type for ECC800, select Device Type or
Device for Linkage Type, and click Confirm.
Step 6 (Optional) If you select Device for Linkage type, select ECC800 for Device name.
Issue 06 (2020-04-22)
You can set parameters under Enable Alarm, Severity, Output Dry Contact and
Loudspeaker based on requirements.
When Enable Alarm is set to Disable for an alarm, the ECC800-Pro will not show
this alarm.
You can set Severity to Critical, Major, Minor, or Warning as required.
After an alarm and a DO output are associated over Output Dry Contact, the
device connected to the DO port will act if the alarm is generated.
If an alarm is associated with the loudspeaker and Loudspeaker is set to Yes, the
loudspeaker produces sound when the alarm is generated.
You can modify alarm parameters in batches over Batch Setting.
The setting methods for different alarms are the same. This section describes how to set
the Operation log full alarm for the ECC800-Pro.
To modify Enable Alarm or Severity in batches, click Batch Setting in the left corner of the Basic Alm
Para page, and choose ECC800 from the Select a device type drop-down list box. Set Destination
Parameter of Enable Alarm or Source Parameter and Destination Parameter of Severity, and click
OK.