Video/RGB/HDMI connection
■Video input cable
Strip off the sheath at both ends of the cable as shown in the figure below to expose outer braided shield for grounding.
The braided shield sections are used for grounding with a cable clamp.
Page 164 Grounding a cable
GOT side
230 or less
(9.06)
■RGB input cable
1.
Wrap the cable shielding material around the cable, and pull out the braided cables for grounding from the cable
shielding material with the length as shown in the figure below.
2.
Install a ferrite core to the cable in the positions as shown in the figure below.
GT2715
GOT side
130 or less
(5.12)
GT2712,GT2710,GT2708
GOT side
40
130 or less
or less
(5.12)
(1.57)
■RGB output cable
1.
Wrap the cable shielding material around the cable, and pull out the braided cables for grounding from the cable
shielding material with the length as shown in the figure below.
2.
Install a ferrite core to the cable in the positions as shown in the figure below.
GOT side
200 or less
(7.87)
40
(1.57)
Ferrite core
(ZCAT3035-1330)
Cable shielding material
Grounding braided wire
(50 (1.97))
Ferrite core
(ZCAT3035-1330)
Cable shielding material
Grounding braided wire
(50 (1.97))
Ferrite core
(ZCAT3035-1330)
Cable shielding material
Grounding braided wire (50 (1.97))
20 or less
(0.79)
Video camera/
vision sensor side
40
400 or less
(1.57)
(15.75)
Vision sensor/
personal computer side
40
or
less
110 or less
(4.33)
(1.57)
Vision sensor/
personal computer side
170 or less
(6.69)
20 or less
200 or less
(0.79)
(7.87)
5 EMC DIRECTIVE AND LOW VOLTAGE DIRECTIVE
Unit: mm (inch)
Unit: mm (inch)
Unit: mm (inch)
External display side
Unit: mm (inch)
5.2 EMC Directive Requirements