*4 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power
distribution network and the machinery within the premises.
Category II applies to equipment that is supplied with power from fixed facilities.
The surge withstand voltage is 2500 V for equipment with ratings up to 300 V.
*5 This indicates the occurrence rate of conductive material in an environment where a device is used. Pollution degree 2 indicates an
environment where only non-conductive pollution occurs normally and a temporary conductivity caused by condensation shall be
expected depending on the conditions.
*6 Some models have ANSI/ISA12.12.01 approval for use in Class I, Division 2 (ANSI/ISA 12.12.01, C22.2 No.213-M1987) hazardous
locations.
For applicable GOT models, refer to the Mitsubishi Electric FA Global Website.
www.MitsubishiElectric.com/fa
*7 When GT2505 is installed vertically, the operating ambient temperature must be between 0°C and 50°C.
*8 If the ambient temperature of GT2505-V exceeds 40°C, observe the maximum absolute humidity that is calculated based on 90% RH at
40°C.
3 SPECIFICATIONS
60
3.1 General Specifications