Gt25Hs-V - Mitsubishi Electric GOT2000 Series Hardware User Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

GT25HS-V

Item
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Vibration resistance
Shock resistance
Operating atmosphere
*1
Operating altitude
*2
Overvoltage category
*3
Pollution degree
Cooling method
Grounding
*1 Do not use or store the GOT under the atmospheric pressure higher than that at an altitude of 0 m.
Doing so may cause a malfunction.
*2 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power
distribution network and the machinery within the premises.
Category II applies to equipment that is supplied with power from fixed facilities.
The withstand surge voltage for the equipment with the rated voltage up to 300 V is 2500 V.
*3 This indicates the occurrence rate of conductive material in an environment where a device is used.
Pollution degree 2 indicates an environment where only non-conductive pollution occurs normally and a temporary conductivity caused
by condensation shall be expected depending on the conditions.
3 SPECIFICATIONS
62
3.1 General Specifications
Specifications
0 °C to 40 °C
-20 °C to 60 °C
10% RH to 90% RH, non-condensing
10% RH to 90% RH, non-condensing
Compliant with JIS B 3502 and
IEC 61131-2
Compliant with JIS B 3502 and IEC 61131-2 (147 m/s
No greasy fumes, corrosive gas, flammable gas, excessive conductive dust, and direct sunlight (as well as at storage)
2000 m or less
II or less
2 or less
Self-cooling
Grounding with a ground resistance of 100 Ω or less by using a ground cable that has a cross-sectional area of 2 mm
more. If impossible, connect the ground cable to the control panel.
Frequency
Under intermittent
5 Hz to 8.4 Hz
vibration
8.4 Hz to 150
Hz
Under continuous
5 Hz to 8.4 Hz
vibration
8.4 Hz to 150
Hz
2
(15 G), 3 times in each X, Y, or Z direction)
Acceleration
Half
Sweep
amplitude
count
3.5 mm
X, Y, or Z
10 times in
2
9.8 m/s
each
direction
1.75 mm
2
4.9 m/s
2
or

Advertisement

Table of Contents
loading