Mitsubishi Electric GOT2000 Series Hardware User Manual page 301

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

■Terminal block 1, 2
*2
GT11H-C□□-37P
Connector for the Handy GOT connection
D-sub 37-pin
Signal name
36, 37
DC24V+
1
FG
18, 19
DC24V-
N.C
N.C
34
SW6
33
SW5
16
SW4
15
SW3
14
SW2
13
SW1
12
SW-COM
*3
31
ES3
*3
32
ES3
N.C
30
KSW-2
29
KSW-1
28
KSW-C
27
DSW-2
26
DSW-2
25
DSW-1
24
DSW-1
23
ES2
22
ES2
21
ES1
20
ES1
*1 The cable for the ES-3 signal is provided in the connector conversion box GT11H-CNB-37S regardless of whether the terminal name
ES-3 is printed on the box or not.
*2 Use C or later version of GT11H-C □ □ -37P.
*3 ES-3 is not provided for B or earlier version of GT11H-C □ □ -37P.
GT11H-CNB-37S
Terminal block
Terminal block 1
1
2
3
4
5
6
7
8
9
10
11
12
Terminal block 2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
7 OPTION AND COMMUNICATION CABLE FOR HANDY GOT
Application
24 V DC power supply "+"
Frame ground
24 V DC power supply "-"
Not used
For Operation switch
For Emergency stop switch
Not used
For Keylock switch
For Grip switch
For Emergency stop switch
7.1 Connector Conversion Box
7
299

Advertisement

Table of Contents
loading

Table of Contents