Precautions (GT27, GT25, GT23, GT2107-W, GT2105)
■Treatment on power cables
For 100 V AC, 200 V AC, and 24 V DC cables, use thick wires as much as possible (Cable cross section: 0.75 mm
2
mm
), and make sure to twist them to the terminals.
To prevent a short circuit due to loose screws, use a solderless terminal with an insulation sleeve.
■Grounding
After connecting the LG terminal and the FG terminal, make sure to connect them to the ground.
Otherwise, the system is susceptible to noise.
The LG terminal has a potential equal to a half of the input voltage.
Therefore, touching the terminal may lead to an electric shock.
For GT2705-V, GT25-W, GT2107-W, and GT2105, ground only the FG terminal because the models do not have the LG
terminal.
Precautions (GT2104-R, GT2104-P, GT2103-P)
■Terminal processing of power cables
Connect a stranded wire or a solid wire directly, or use a rod terminal with an insulation sleeve.
Do not tighten the terminal screws in the specified torque range or more. Doing so can cause a failure or malfunction.
• When connecting a stranded wire or a solid wire directly
Twist the end of the stranded wire to prevent the elemental wires from protruding.
Do not apply solder plating on the wire terminal.
Approx.
5 mm
(0.20inch)
• When using a rod terminal with an insulation sleeve
A wire with a thick sheath cannot enter the insulation sleeve smoothly. Select a wire referring to the figure of external
dimensions below.
Insulation sleeve
2mm to 2.5 mm
(0.08inch) to (0.10inch)
Manufacturer
PHOENIX CONTACT
■Tool
Tighten the power supply terminal using a commercially-available small screwdriver. The tip of the screwdriver must be
straight and as wide as the shaft, as shown in the figure below.
Straight tip
0.4mm
2.5mm
(0.02inch)
(0.10inch)
Manufacturer
PHOENIX CONTACT
■Grounding
Make sure to ground the FG terminal.
Otherwise, the system is susceptible to noise.
Contact part
6mm
(0.24inch)
10.5mm to 12 mm
(0.42inch to 0.48inch)
Swage
CRIMPFOX 6
Model
SZS 0.4 × 2.5
8 WIRING OF POWER SUPPLY SECTION