13.3
Cable Bend Radius for GT25 with an Extension
Unit
The following shows the cable bend radius for the GOT with one extension unit.
Rear face
R
Extension unit
If the cable from the extension unit does not hang below the bottom of the GOT, dimension A is smaller than
dimension B.

GT2512-S, GT2512F-S

Unit: mm (inch)
Model
*4
GT25-J71E71-100
GT15-QBUS
GT15-QBUS2
GT15-75QBUSL
GT15-75QBUS2L
*1
GT15-RS2-9P
*1
GT15-RS4-9S
*1
GT15-RS4-TE
GT15-J71LP23-25
GT15-J71BR13
*4
GT25-J71GN13-T2
GT15-J71GP23-SX
*4
GT15-J71GF13-T2
GT15-J61BT13
GT25-FNADP
GT15-PRN
GT15-DIO
GT15-DIOR
GT15-SOUT
*1 For cables prepared by the user, the dimensions in the table are not applied.
*2 If the cable from the extension unit does not hang below the bottom of the GOT, the dimension is 0.
*3 For details of the cable for GT15-J71LP23-25 (optical loop unit), contact your local Mitsubishi Electric System & Service Co., Ltd.
*4 The bend radius depends on the Ethernet cable to be used.
Rear face
(Open frame model)
B
A
C
Extension unit
A
38(1.50)
88(3.46)
88(3.46)
72.5(2.85)
33.5(1.32)
*3
79(3.11)
65(2.56)
65(2.56)
65(2.56)
47(1.85)
-
52(2.05)
77(3.03)
41(1.61)
B
A
R
C
*2
B
C
81(3.19)
0
85(3.35)
3(0.12)
3(0.12)
0
0
*3
0
81(3.19)
0
85(3.35)
0
0
0
-
0
0
0

13.3 Cable Bend Radius for GT25 with an Extension Unit

R (cable bend radius)
34(1.34)
50(1.97)
50(1.97)
27.5(1.08)
-
*3
30(1.18)
26(1.02)
15(0.59)
26(1.02)
28(1.10)
-
18(0.71)
43(1.69)
30(1.18)