Description
This system supports following built-in simple security features in a system.
• Warning Message (Watch mode)
Automatically and periodically send the Watching (VRS) Message from built-In Speaker on Multiline
terminal or external paging adapter during night mode.
Enable to accommodate with 3rd Party PIR (Passive Infrared Sensor) or Emergency Button to pro-
vide security feature such as Auto-Emergency Call with Warning (VRS) Message sending.
• Room Monitoring from Outside
S
Access Multiline terminal from outside to monitor the room sound
• Remote Inspection
Automatically ring the terminal with pre-programmed schedule in order to check whether users an-
swer or not. If not answered Emergency Call is placed to predefined destination automatically.
Conditions
Warning Message (Watch Mode)
• Watch mode can provide "Watching message" in a preprogrammed interval via internal paging group
terminals and/or external paging group during defined schedule such as night time.
• Watch mode start and stop automatically according to PRG20-47-01 setting.
• Watch mode can start and stop manually by Service code (PRG11-12-63) or function key (
signment.
• To connect security sensor it need to set PRG 20-46-01 Sensor mode (1; on) and connect to Door
Phone port instead of Door phone.
• Security sensor can be connected 6, 7 port of 408M-A1 . Max 8 sensors can be connected.
PRG82-21 needs to set up according to used sensor.
• Security sensor can start and stop automatically according to PRG20-48-01 setting.
• Security sensor can start and stop manually by Service code (PRG11-12-64) or function key (
assigned).
• When system received sensor detection, following 1, 2 or both will be happened.
1. Repeated "Warning message" is provided via internal paging group terminals and/or external
paging group.
2. Emergency call can be placed to pre-programmed destination with pre-recorded VRS message.
After finishing VRS message, destination person can monitor the situation using Multiline terminal
defined at PRG20-46-10. Also By pressing * key from outside it is possible to make both way talk.
• If all VRS channels are busy, tone will be provided instead of VRS message, such as Watch, Warn-
ing or for destination message.
• If VRS message itself is not recorded, tone will be provided.
• VRS message can be provided from extension Speaker only when extension is idle. But if Watch or
Warning message happened during normal paging is working, normal paging will stop and send
Watch or Warning message.
• If Watch message and Warning message occurred simultaneously, Warning message have high pri-
ority.
• If multiple Sensor detected and multiple Warning message occurred at same time, latest detected
Sensor's Warning message will be provided.
• Activation or stop of Sensor itself has to operate according to used sensor specification.
• If outgoing call restriction is set, emergency call number needs to pre-registered in restriction allow
table, then emergency call can go through. Also even all trunk are busy, the call has high priority and
can go out.
• If destination does not answer to emergency call, system repeat placing call specified times set at
PRG20-46-08.
• To stop Warning message or emergency call, Service code for cancel "Warning message" (PRG11-
12-62) needs to set.