ISSUE 1.0
• During Watching mode or Security sensor "On" state, even system reset occurred these modes will
be continued after boot up.
• During sending "Warning message" or placing emergency call, if system reset occurred these state will be
cleared. So after boot up "Warning message" or placing emergency call will stop.
• If Sensor mode is set (PRG20-46-01;1) and SLT is connected instead of sensor, off hook of SLT makes situa-
tion like sensor has detected.
Room Monitoring from outside
• To work Room Monitoring feature, caller ID of outside caller and monitored extension number have to
set. Monitored extension can be set at PRG13-04-03/04, also these PRG can be set by pressing
Transfer key at Speed Dial name setting screen of outside caller.
1. Press Transfer key.
2. Select TRF Mode, 3 (Remote Monitor).
3. Enter monitored extension number and press HOLD key.
• Room monitor can be work only when set extension is idle state, other state busy tone (ISDN trunk)
or ringback tone (Analogue trunk) will be sent to outside caller. During Room Monitor is working the
terminal have "Remote Monitored" indication on LCD and can not be operated.
• By pressing
key from outside it is possible to make both way talk.
*
• If same outside caller number is register to both Room Monitor and Distinctive ring, feature set in
youngest Speed Dial bin is used.
• If same outside caller number is register to multiple Room monitor extension, youngest Speed Dial
bin setting is used.
Remote Inspection
• When Remote inspection is set to the terminal, "Confirm" and "Ring time" are displayed on Multiline
terminal LCD.
• If Remote inspection set terminal is busy (receiving another incoming call or on call state), inspection
ring will be start after finishing these previous call.
• When the terminal does not answer to inspection ringing over the time set at PRG20-45-03, emer-
gency call will be placed to pre-programmed destination with pre-recorded VRS message.
• After finishing VRS message, destination person can start monitoring of inspection terminal. Also by
pressing
key from outside it is possible to make both way talk.
*
• If outgoing call restriction is set, emergency call number needs to pre-registered in restriction allow
table, then emergency call can go through. Also even all trunk are busy, the call has high priority and
can go out.
• If destination does not answer to emergency call, system repeat placing call specified times set at
PRG20-45-07.
• Max 6 extension can be set as Remote Inspection terminal.
• If all VRS channels are busy, tone will be provided instead of VRS message, such as for inspection
message or for destination message.
• If VRS message itself is not recorded, tone will be provided.
Emergency call destination Must be set considering this feature's purpose.
Emergency Call 1
Emergency calls when "Security Sensor" or "Remote Inspection" performed, SMDR can record these
call class as follows.
• Security Sensor: SAD
• Remote Inspection: WAD
Emergency Call 2
Emergency calls when "Security Sensor" or "Remote Inspection" performed, alarm report can record
these alarm and alarm display terminal indicates following on LCD.
• Security Sensor: 31: Sensor detect
• Remote Inspection: 32: Confirm dial