Timer Class
0
24-01-04
24-01-06
24-02-03
24-02-04
F
25-07-02
25-07-03
25-07-07
25-07-08
25-07-09
25-07-10
31-01-02
Conditions
• Timer Classes are used for CAR/VE also.
• When Timer Class is set to 0 it uses the system-wide timers.
• All stations and trunks are assigned to Timer Class 0 at default.
• Both system-wide timers (Timer Class 0) and Timer Class timers (Timer Class 1~15) can be used in
the same system.
Default Settings
Timer Class set to 0 for all trunks and extensions.
System Availability
Terminals
All Multiline Terminals
1-220
Timer Class
1~15
20-31-13
Exclusive Hold Recall Callback Time
20-31-14
Park Hold Time - Normal
20-31-15
Delayed Call Forwarding Time
20-31-16
Transfer Recall Time
20-31-17
VRS/DISA No Answer Time
20-31-18
Disconnect after VRS/DISA
Re-transfer to IRG
20-31-19
Long Conversation Warning Tone
Time
20-31-20
Long Conversation Disconnect Time
20-31-21
DISA Internal Paging Time
20-31-22
DISA External Paging Time
20-31-23
Page Announcement Duration
Title
An Exclusive Hold Recall rings an extension for this
time. If not picked up, the call goes back on Non
exclusive Hold. Station Timer Class is referred by
held call.
A call left parked longer than this time recalls the
extension that initially parked it. Trunk or Station
Timer Class is referred by held call.
If activated at an extension, No Answer Call
Forwarding occurs after this time. Station Timer
Class is referred by the station sets No Answer Call
Forward.
A transferred call recalls to the extension that
initially transferred it after this time. Station Timer
Class is referred by transferred call.
After this time expires, the call follows the
programmed Ring No Answer routing (Program
25-03 and 25-04-01). Trunk Timer Class is referred.
Disconnect after re-transfer to Incoming Ring
Group. Trunk Timer Class is referred.
Determine the time trunk-to-trunk conversation can
talk before the Long Conversation tone is heard.
Trunk Timer Class is referred.
This timer determines how long the system waits
before disconnecting a trunk-to-trunk conversation
call after the Long Conversation tone is heard.
Trunk Timer Class is referred.
This is the maximum length of an Internal Page
placed by a DISA caller. If the Page continues
longer than this time, the system terminates the
DISA call. Trunk Timer Class is referred.
This is the maximum length of an External Page
placed by a DISA caller. If the Page continues
longer than this time, the system terminates the
DISA call. Trunk Timer Class is referred.
This timer sets the maximum length of External
Page announcements. Station or Trunk Timer
Class is referred by the caller makes
announcement.
ISSUE 1.0
Comment
Flexible Timeouts