The descriptions that follow relate to the positioning data set items [Da.1] to [Da.10],
[Da.20] to [Da.22].
(The buffer memory addresses shown are those of the "positioning data No. 1".)
• Guide to buffer memory address
In the buffer memory address, "n" in "6001+1000n", etc. indicates a value
corresponding to axis No. such as the following table.
Axis No.
n
Axis No.
1
0
2
1
3
2
4
3
(Note-1): Calculate as follows for the buffer memory address corresponding to each axis.
(Example) For axis No. 16
6001+1000n ([Da.10] M code/Condition data No./Number of LOOP to LEND
repetitions) = 6001+1000 15 = 21001
Chapter 5 Data Used for Positioning Control
n
Axis No.
5
4
9
6
5
10
7
6
11
8
7
12
5 - 65
n
Axis No.
n
8
13
12
9
14
13
10
15
14
11
16
15