Mitsubishi Electric MELSEC-Q Series User Manual page 353

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

Setting item
[Cd.6] Restart command
: Refer to Section 5.7 "List of control data" for details on the setting details.
Signal name
PLC READY signal
READY signal
All axis servo ON
Synchronization flag
Interface
Axis stop signal
signal
M code ON signal
Error detection signal
BUSY signal
Start complete signal
Forced stop input signal
Stop signal
External
signal
Upper limit (FLS)
Lower limit (RLS)
: When the synchronous setting of the PLC CPU is made in the nonsynchronous mode, this must be
provided as an interlock.
When it is made in the synchronous mode, no interlock must be provided in the program because the flag is
turned ON when calculation is run on the PLC CPU.
(6) When stopped with interpolation operation, write "1: Restarts" into "[Cd.6]
Restart command" for the reference axis, and then restart.
(7) If the PLC READY signal is changed from OFF to ON while stopped, restarting
is not possible.
If restart is requested, the warning "Restart not possible" (warning code: 104)
will occur.
(8) When the machine HPR and fast HPR is stopped, the error "HPR restart not
possible" (error code: 209) will occur and the positioning cannot restarts.
(9) If any of reference partner axes executes the positioning operation once after
interpolation operation stop, the warning "Restart not possible" (warning code:
104) will occur, and the positioning cannot restarts.
[3] Control data requiring setting
Set the following data to execute restart.
Setting
value
1
Set "1: Restarts".
[4] Starting conditions
The following conditions must be satisfied when restarting. (Assemble the
required conditions into the sequence program as an interlock.)
(1) Operation state
"[Md.26] Axis operation status" is "1: Stopped".
(2) Signal state
ON PLC CPU preparation completed
ON QD77GF preparation completed
ON All axis servo ON
ON
OFF Axis stop signal is OFF
OFF M code ON signal is OFF
OFF There is no error
OFF BUSY signal is OFF
OFF Start complete signal is OFF
ON There is no forced stop input
OFF Stop signal is OFF
ON Within limit range
ON Within limit range
Chapter 6 Sequence Program Used for Positioning Control
Setting details
Signal state
QD77GF buffer memory
Accessible
6 - 71
Buffer memory address
4303+100n
n: Axis No.-1
Device
Y0
X0
Y1
X1
[Cd.180] Axis stop
[Md.31] Status: b12
[Md.31] Status: b13
X10 to X1F
[Md.31] Status: b14