Part 7: Common Reference Material
(3) Read the servo parameters.
Click [Parameters] in the menu to display the parameter list screen.
Connect the MR-J2S-_A_/MR-J2S-_CP_/MR-J2S-_CL_ servo amplifier to a personal computer and click
the [Read All] button.
Change the setting value of [Pr. PA19 Parameter writing inhibit] to "000E" and click the [Write] button.
Then turn off/on the power of the servo amplifier.
Click the [Read All] button again to extend the display range of parameter numbers and display the
parameters in the list of parameters.
After reading the parameters is completed, Select [File] - [Save] to save the parameter file.
(The work with the setup software (MRZJW3-SETUP161E) is finished.)