Part 7: Common Reference Material
MR-J2S-_A_
No.
Name
45
Input signal selection 4
MR-J4-_A_
Type
Target
No.
Type
_ _ _ X
Hex
PD13
Hex
_ _ X _
Hex
_ X _ _
Hex
Hex: hexadecimal parameter; Dec: decimal parameter
7 - 57
Conversion rule
Target
When the setting value of No. 0 is _ _ _ 0, _ _ _
2, or _ _ _ 4 or when the value of No. 42 is other
than _ _ _ 2, this parameter will be converted.
The setting value will be converted as shown in
Table 1 (as input) in Section 2.3.5 (6).
However, a setting value other than those in
Table 1 (as input) in Section 2.3.5 (6) will be
converted to _ _06. (CR)
_ _ XX
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
When the setting value of No. 0 is _ _ _ 0, _ _ _
2, or _ _ _ 4 or when the value of No. 42 is other
than _ _ _ 2, this parameter will be converted.
The setting value will be converted as shown in
Table 2 (as input) in Section 2.3.5 (6).
However, a setting value other than those in
Table 2 (as input) in Section 2.3.5 (6) will be
converted to 20_ _. (SP1)
XX _ _
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.
When the setting value of No. 0 is _ _ _ 0, _ _ _
2, or _ _ _ 4 or when the value of No. 42 is other
than _ _ _ 2, this parameter will be converted.
The setting value will be converted as shown in
Table 3 (as input) in Section 2.3.5 (6).
However, a setting value other than those in
Table 3 (as input) in Section 2.3.5 (6) will be
converted to _ _20. (SP1)
_ _ XX
When conversion of I/O signal assignment is
enabled, this parameter will be converted
according to the control signal connection of the
renewal tool.
When conversion of I/O signal assignment is not
enabled, the initial value will be used.
This parameter can be used with MR
Configurator2 of software version 1.53F or later.