Mitsubishi Electric MELSERVO-J2S Series Transition Handbook page 72

Servo amplifiers & motors
Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

Part 2: Review on Replacement of MR-J2S-_A_ with MR-J4-_A_
MR-J2S-_A_
No.
Name and function
60
Low-pass filter/adaptive vibration suppression control
Select the low-pass filter/adaptive vibration suppression
control.
0
Low-pass filter selection
0: Available (Automatic adjustment)
1: Disabled
When available is selected, the filter in
the zone expressed by the following
formula is automatically set.
For 1 kW or less
VG2 setting value × 10
2π × (1 + GD2 setting value × 0.1)
For 2 kW or less
2π × (1 + GD2 setting value × 0.1)
Adaptive vibration suppression control
selection
If "available" or "maintained" is
selected in the adaptive vibration
suppression control selection,
machine resonance control filter 1
([Pr. 58]) will become ineffective.
0: Disabled
1: Enabled
Usually, machine resonance
frequency is detected, and a filter
corresponding to the resonance
is generated to control the
machine vibration.
2: Maintenance
Until then, detection of machine
resonance is stopped by keeping
the characteristics of the filter
generated until that moment.
Adaptive vibration suppression control
selection
Select Adaptive vibration suppression
control.
0: Normal
1: High sensitive
61
Load to motor inertia ratio 2
Used to set the load to motor inertia ratio when gain
switching is enabled.
Setting range: 0 to 3000; Unit: x 0.1
[Hz]
VG2 setting value × 5
[Hz]
Initial
No.
value
0000h
PB23 Low-pass filter selection
0
0
0
Set "0000 (automatic setting)".
PB18 Low-pass filter setting
One of the following statuses is applied, depending
on how [Pr. PB23] is set.
PB23
_ _ 0 _ (Initial value)
_ _ 1 _
_ _ 2 _
Nothing needs to be set due to automatic setting.
PB01 Adaptive tuning mode (adaptive filter II)
0
0
0
70
PB29 Gain switching load to motor inertia ratio
Used to set the load to motor inertia ratio when gain
switching is enabled.
This parameter is enabled only when "Manual mode
(_ _ _ 3)" is selected in "Gain adjustment mode
selection" of [Pr. PA08].
Setting range: 0.00 to 300.00; Unit: x 1.0
Note that the setting unit is different from that for
MR-J2S-_A_.
When setting a value, set a value 0.1 x the
MR-J2S-_A_ setting value.
2 - 41
MR-J4-_A_
Name and function
Low-pass filter
0: Automatic setting
1: Manual setting
2: Disabled
PB18
Automatic setting
Setting value enabled
Setting value disabled
Adaptive filter tuning
0: Disabled
1: Automatic setting
(Do not use this in the torque
control mode.)
2: Manual setting
Control
Initial
mode
value
0000h
P
S
3141
P
S
0000h
P
S
T
7.00
P
S

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMelservo-j2m seriesMelservo-j4 seriesMr-j2s-10aMr-j2s-20aMr-j2s-40a ... Show all

Table of Contents