Harness
1
Main
2
Main
Pass
There is no resistance (0–5 ohms) between wire ends. Go to Step 4.
Fail
There is high resistance or open between wire ends. Repair or replace all damaged wire. Go to
Returning the Machine to Service (page 21)
Step 4: Test the DC alternator.
Note:
For gasoline engines, refer to the Briggs and Stratton DC alternator output performance test in Chapter
3 (Gasoline Engine) of the Greensmaster TriFlex 3320/3420 Service Manual. For diesel engines, refer
to the Kubota SM-E3B Series DC alternator output performance test in Chapter 4 (Diesel Engine) of the
Greensmaster TriFlex 3320/3420 Service Manual.
Pass
The alternator DC output performance test passed. Repeat the diagnostic process.
Fail
The alternator DC output performance test did not pass. Replace the DC alternator as shown in the
Engine chapter of the Greensmaster TriFlex 3320/3420 Service Manual. Refer to
Machine to Service (page
Pin
Connector
P01
12
White (W)
P12
2
White (W)
21).
Wire
Expected
Color
Reading
Open
(infinite)
and follow the steps listed.