Location
Harness
1
Main
2
Main
CAUTION
Overtightening the harness connector retaining fastener will damage the primary TEC
controller.
After you plug connector P01 back into the TEC, torque the retaining fastener for P01 to 25–28
in-lbs.
Pass
The wiring test passed. Go to Step 9.
Fail
The wiring test did not pass. Repair or replace the faulty wiring. Go to
Service (page 21)
Step 8: Test the leak detector alarm.
1.
Remove the leak detector alarm from the machine.
2.
Bench test using 12 V power on one side, and ground on the other. The alarm should sound.
Pass
The leak detector alarm test passed. Begin the diagnostic process again.
Fail
The leak detector alarm test did not pass. Replace the alarm. Go to
Service (page 21)
Pin
Connector
P01
7
Pink (PK)
P38
2
Pink (PK)
and follow the steps listed.
and follow the steps listed.
Wire
Expected
Color
Reading
less than
2 ohms