3.
Disconnect both main harness connectors from the cutting reel motor cable connectors mounted on
the traction unit.
4.
Inspect the 2 cutting reel motor cable connectors and the 2 main harness connectors for damage,
corrosion, debris, and proper alignment of the pins inside the connectors.
Pass
The wiring inspection passed. Go to Step 4.
Fail
One or more of the inspection checks failed. Repair or replace the worn or damaged parts. Go to
Returning the Machine to Service (page 21)
Step 4: Swap cutting reel motors between cutting units.
All of the cutting reel motors are identical.
1.
Disconnect the 48 V power to the cutting reel motors. Refer to
V Power to the Cutting Reel Motors (page
2.
Locate cutting unit 1.
1. Cutting unit 1 (center), which includes reel motor 1
2. Cutting unit 2 (left), which includes reel motor 2
1.
Disconnect the cutting units from the 48 V power system by separating the cutting unit power connectors.
This prevents unexpected operation of cutting units. Refer to
V Power to the Cutting Reel Motors (page
2.
Swap cutting reel motor 2 with a cutting reel motor from a different cutting unit. You can obtain more
information on replacing the cutting reel motor in Chapter 5 of the Greensmaster TriFlex 3320/3420
Service Manual
3.
Connect the cutting units to the 48 V power system by plugging the cutting unit power connectors together.
Refer to
Connecting and Disconnecting the 48 V Power to the Cutting Reel Motors (page
4.
Operate the machine.
and follow the steps listed.
Connecting and Disconnecting the 48
18).
Figure 141
3. Cutting unit 3 (right), which includes reel motor 3
Connecting and Disconnecting the 48
18).
247