Pass
The wiring between the controller and the motor/generator passed inspection. Go to Step 5.
Fail
The wiring between the controller and the motor/generator did not pass inspection. Only repair
wiring that has worn insulation or a recessed connector pin. Replace all components that have
damaged, burned, or broken wiring. Go to
the steps listed.
Step 5: Install a replacement controller onto the starter/generator.
Install a replacement controller onto the S/G. Refer to Chapter 6 of the Greensmaster TriFlex 3320/3420 Service
Manual. Use the applicable parts of the Generator Assembly Service section.
Step 6: Install the starter/generator assembly.
Install the S/G assembly back into the machine. Refer to Chapter 6 of the Greensmaster TriFlex 3320/3420
Service Manual. Use the Installation procedure in either the Generator Assembly (Greensmaster 3320) section
or the Generator Assembly (Greensmaster 3420), depending on your machine.
Step 7: Use Toro DIAG to program the S/G.
1.
Connect a PC with Toro DIAG software to the machine via a Toro DIAG Cable (Part No. 115-1944). Refer
to
Toro DIAG–Quick Start (page
2.
Use the Toro DIAG software to reprogram the machine in accordance with Toro DIAG User's Guide. The
replacement S/G controller is programmed during the reprogramming of the machine.
3.
Once programming is complete, disconnect the Toro DIAG cable from the machine.
4.
Go to
Returning the Machine to Service (page 21)
Returning the Machine to Service (page 21)
22).
and follow the steps listed.