Fault 81: Start Relay - Overcurrent - Toro Greensmaster TriFlex 3300 Manual

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Fault 81: Start Relay – Overcurrent
InfoCenter Display:
Fault Description
Output current voltage to the starter relay coil is too high.
Circuit Description
When the key switch is turned to the R
TEC, and the start relay is activated. When this happens, the key switch may be turned to the S
and the starter solenoid will be engaged, which will activate the engine's starter motor.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
_____FAULT
#81____
RELAY COIL -
OVER
or S
position, a signal is sent from the key switch to the primary
UN
TART
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 21)
200
position
TART
19).
and follow the steps listed.