Fault 132: Internal TEC Controller Fault
InfoCenter Display:
Fault Description
The primary Toro electronic controller (TEC-5001) reports this fault when it detects a software fault exists
within the primary TEC.
Circuit Description
The primary TEC controller monitors the condition of various machine switches and sensors (inputs) and directs
electrical power to control machine functions (outputs) based on the state of the inputs. The T1 is primarily
responsible for managing the engine start signal and interlocks.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Shut off the engine.
3.
Start the engine.
4.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Contact the Toro Technical Assistance Center for assistance.
Note:
You must fix this software fault. Accomplish the TEC software repair with direct assistance
from Toro.
_____FAULT
#132____
INT. DEVEL.
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 21)
307
19).
and follow the steps listed.