Location
Harness
1
Main
2
Main
Pass
The resistance tests passed, but the voltage readings in Step 3 are still bad.
Note:
Do not go to Step 5 until after the voltage readings in Step 3 are good.
Fail
One or more of the power and ground wiring tests failed. Repair or replace the worn or damaged
parts. Go to
Step 5: Swap cutting reel motors between cutting units.
All of the cutting reel motors are identical.
1.
Locate cutting reel motor 1.
1. Cutting unit 1 (center), which includes reel motor 1
2. Cutting unit 2 (left), which includes reel motor 2
2.
Verify that the cutting units are disconnected from the 48 V power system (the cutting unit power
connectors are separated). This prevents unexpected operation of cutting units. Refer to
Disconnecting the 48 V Power to the Cutting Reel Motors (page
3.
Swap cutting reel motor 1 with a cutting reel motor from a different cutting unit. You can obtain more
information on replacing the cutting reel motor in Chapter 5 of the Greensmaster TriFlex 3320/3420
Service Manual
Pin
Connector
P17
1
P09
4
Returning the Machine to Service (page 21)
Wire
Expected
Color
Reading
White (W)
30k to 32k
Black
ohms
(BK)
(48 V
Ground)
and follow the steps listed.
Figure 152
3. Cutting unit 3 (right), which includes reel motor 3
4.
272
Connector Graphic
18).
g225145