Fault 67: S1 Enable - Current Too High - Toro Greensmaster TriFlex 3300 Manual

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Fault 67: S1 Enable – Current Too High
InfoCenter Display:
Fault Description
This fault is reported when the primary TEC-5001 controller determines that the S1 solenoid coil current
is too high.
Circuit Description
The primary TEC controller uses inputs from various machine switches to determine when to energize lift
manifold solenoid valves. One output from the primary TEC controller drives the coil for solenoid S1.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Test the resistance of the coil for solenoid S1.
1.
Go to
Preparing for Troubleshooting and/or Testing (page 20)
2.
Remove the right side cover.
_____FAULT
#67_____
S1 COIL - OVER
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 21)
173
and follow the steps listed.
and follow the steps listed.
19).