Table
7-2
loop
Requirements
,
Device
Max Loop Resistance
Max Distance
from
Number
of
Description
Interface
PCB
(Including
Device)
KSU to Device
Wire Pairs'
Digital
PDKU (ckts 1 - 8)
telephone
or
40 ohms
1000 ft. (303 m)
1 -pair
RDSU (ckts 5 - 8)
DDSS console
PDKU (ckt 8)
40 ohms
1000 ft. (303 m)
1 -pair
Attendant
console
RATU-(ckts 1 - 4)
40 ohms
1000 ft. (303 m)
2-pair
RPCI-DI
PDKU (ckts 1 - 8)
or
or
PDIU-D12
RDSU (ckts 5 - 8)
40 ohms
1000 ft. (303 m)
Shares digital
telephone
wire-pair?
PDIU-DS
PDKU (ckts 1 - 8) or
RDSU (ckts 5 - 8)
40 ohms
1000 ft. (303 m),
1 -pair
ADM
PDKU (ckts 1 - 8) or
RDSU (ckts 5 - 8)
40 ohms
1000 ft. (303 m)
Shares digital
telephone
wire-pair.3
DDCB
PDKU or
RDSU (ckt 5)
40 ohms
1000 ft. (303 m)
1 -pair
HDCB
PEKU (ckt 5)
or
PESU2
(ckt 5)
40 ohms
1000 ft. (303 m)
2-pair
HDSS consoles
PEKU (ckts 7 & 8)
Standard
RSTU (ckts 1 - 8)
telephones,
RDSWRSTS
(ckts 1 - 4)
voice mail,
PSTU (ckts 1 - 8)
auto attendant,
or
etc.
PESU*
(ckts 1 & 2)
20 ohms
l
300 ohms 4
l
600 ohms
l
1,200 ohms
500 ft. (152 m)
l
300 ohms, Approx.
3000 ft. (909 m)
l
600 ohms, Approx.
9000 ft. (2,727 m)
l
1200 ohms, Approx.
21,000 ft. (6,363 m)
(with 150 ohm device.
See manufacturer's
product specifications
for exact resistance of
device).
1 -pair
EKTs
PEKU or PESU
40 ohms
1000 ft. (303 m)
2-pair
OCA Stations
need 3-pair.
RATI
RATU (ckts 1 - 4)
40 ohms
1000 ft. (303 m)
1 or 2-pair
Notes:
DKOOOZ+C2
1. Use 24 A WG twisted pairs.
2. PESU circuits 3 and 4 are not used.
3.
Two-pair
wire or an optional
telephone
power supply is required
to achieve
maximum
range.
4. 300 ohms for PSTU/PESU;
600 ohms for RSTU, RDSU/RSTS/RSTU2
without R48S option, and 1200 ohms for RSTU or
RDSU equipped
with an optional
R48S.
January 1996