Toshiba Strata DK 280 Installation Manual page 632

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Programs
45 - 48-Use
to define
Toll
Table 11-4
Restriction for any line.
Transmit Equalizer Setting Switch
Programs
50 w 56-Use
to define Least Cost
Routing assignments.
Program
59-Use
to assign
11 lines
to
attendant
console buttons.
Program
71 - 74-With
DK280
Release '3
and above, these programs
are used in place
of Program
*09 to assign
DID/tie/DNIS
line
ringing destinations.
Program
78-Use
to assign special ringing of
lines: includes
Night Ring Over Page, DISA,
Remote
Maintenance
via
the
Internal
Maintenance
Modem
(IMDU),
and Built-in
Auto Attendant.
Programs
81 - 89-Use
to assign loop and
ground start RDTU CO lines to ring selected
stations on incoming calls.
Programs
*81 - *83-With
DK280 Release
3, these
Programs
are used to designate
which DNs will flash when a CO line rings a
telephone.
SHORT
MEDIUM
LONG
o- 150ft
150-450ft
450 - 655 ft
Sl
ON
OFF
OFF
s2
OFF
ON
OFF
s3
OFF
OFF
ON
s4
OFF
ON
OFF
s5
OFF
OFF
ON
s6
OFF
ON
OFF
s7
OFF
OFF
ON
s8
NOT USED
NOT USED
NOT USED
DK0514
P3: FUTURE
P4: REMOTE LOOP
USE
BACK TEST
I
(SEE FIGURE 1 l-9)
11.5
RDTU Hardware
and Cabling
Installation
11.5.1
RDTU
Cable
Length
Switch
The distance between
the DK280, RDTU and CSU or
RDTU to other Customer
Premise Equipment
(CPE)
Tl may vary (O-655
ft.) as shown
in Figures
11-1,
11-2, and 1 l-3. The RDTU interface transmitter
must
be equalized
and its impedance
must be matched
to
the cable length connecting
the RDTU to the CSU or
other
CPE,
Tl.
RDTU
transmit
equalization/
impedance
matching
is accomplished
by setting
RDTU SW1 for the proper cable length
(see Figure
11-5 for SW1 location and Table 1 l-4 for SW1 setting
instruction).
11.5.2
RDTU
Loop
Back Jumper
Plugs
The RDTU PC9 provides jumper plugs for Loop back
testing. Loop back tests are described
in Section 11.6
of this chapter.
11.5.3
RDTU
Front
Panel Indicators
The RDTU
PC9 provides
seven
LED indicators
to
show
the status
of RDTU:
Busy or Idle condition,
Alarm
status,
and
Synchronization
status.
A
description
and the function
of each status
LED is
provided below (see Figure 11-5).
BSY
FALM
MFAL
i%ki
PSYN
SSYN
DK0513
-
LED STATUS
INDICATORS
(PARAGRAPH
4.03)
EQUALIZER
SE-ITING SWlTCt
(PARAGRAPH
4.01)
RDTU SELF TEST
NETWORWCSU
TEST
(SEE FIGURES I 1-7 AND 11-8)
Figure 11-5
RDTU Printed Circuit Board
11-8
January
1996