use Program
*04,
*09, *71 - *73, or 71 (1 - 3) as
required.
Each port assigned
to the same Program
31 Voice
Mail Group
should
also be assigned
to the same
distributed
hunt group. Each Voice Mail Group should
be assigned to a unique (different) DH group.
Program
*41 Series-T1
Span Assignments
Tl parameters
and assignments
are made with the
Program
*41 series (along
with the Program
*42
series).
The RCTUC/D
common
control
unit can
support
up to six
RDTUs,
and
the
RCTUB,
RCTUBA/BB
unit can support
up to two; and the
RCTUA cannot support
the RDTU. (See Chapter
11
-Tl
for additional Tl programming
information.)
Program
*41-l
Tl Span Frame and Coding
Assignments
4
Tl Span Framing
Assignments,
LED 01-Each
RDTU
PCB can be individually
assigned
for
Superframe
or Extended
Superframe.
LED 01
should be off for Super-frame, or ON for Extended
Superframe.
n
Tl Span Line Code Assignments,
LED 02-Each
RDTU PCB can be individually assigned for B8ZS
or AMI coding. LED 02 should be on for B8ZS, or
OFF for AMI.
Program
*41-2
Tl Channel
Assignments
RDTUs provide 8, 16, or 24 channels,
each of which
can operate
independently
as CO lines (ground start
or loop start), tie lines (Wink or Immediate
Start), or
DID lines (Wink or Immediate
Start).
Assign
the
number of channels for each RDTU with Program 03.
IMPORTANT!
Program
91-2 must be run or System Power
must be momentarily
turned OFF (5 seconds)
then ON for Program *41-2 to take effect.
Program
*41-3,
Tl Span Transmit
Level Pad
Assignments
The transmission
path of each RDTU can be set for
one of several PAD settings:
n
Enter 1 for +6 decibel (dB) padding
n
Enter 2 for +3 dB
n
Enter 3 for 0 dB
n
Enter 4 for -3 dB
6
Enter 5 for -6 dB (initialized setting)
.
q
Enter 6 for -9 dB
q
Enter 7 for -12 dB
n
Enter 8 for -15 dB
Program
*41-4,
Tl Span Receive Level Pad
Assignments
The receive level of each RDTU can be set for one of
several PAD settings
n
Enter 1 for +6 decibel (dB) padding
I
n
Enter 2 for +3 dB
n
Enter 3for 0 dB
n
Enter 4 for -3 dB (initialized setting)
H
Enter 5 for -6 dB
w
Enter 6 for -9 dB
n
Enter 7 for -12 dB
n
Enter 8 for -15 dB
Program
*42 Series-T1
Span Timing
Reference
Assignments
Timing references
for Tl RDTU PCBs are made with
the Program *42 series. (Other RDTU parameters, are
made with the Program *41 series and Program 03.)
For proper Tl operation,
the equipment
at each end of
a Tl span line must be synchronized.
The DK280 is
synchronized
(as slave) to the equipment
on the other
end of the Ti line by the RDTU PCB designated
as
the Primary Reference
in Program *42-l.
If a malfunction
occurs and Primary Synchronization
is
lost, the DK280
automatically
switches
modes
and
synchronizes
to the equipment
connected
to the
RDTU PCB designated
as the Secondary
Reference.
If the equipment
on the other end of the DK280 Tl
lines should synchronize
to the DK280 clock source,
then blanks should be entered in Program *42 1 and
2. In this case, the DK280
clock runs free and is
considered
the Master Synchronization
source.
The
RCTUC/D
common
control unit can support up to six
RDTUs,
and the the RCTUB,
RCTUBA/BB
unit can
support up to two. The RCTUA and RCTUA3
cannot
support the RDTU. (See the Tl Chapter of this manual
for more information
on Program *42.)
January
1996
9-27