Set-Up; Local Operation; Remote Terminal Operation; Requirements - Toshiba Strata DK 280 Installation Manual

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

5.
Set the terminal parameters
to:
Word length: 7 bits
Stop bits: 1
Parity: Even
13.5.3
local
Operation
Use the procedure
below to establish communications
between
the local terminal
and the PIOU(S) so that
programming
may be accomplished
via the terminal.
,
1.
Set-up
the terminal
as described
in Paragraph
13.5.2.
2.
Set the terminal to on-line.
3.
Set Caps
Lock
on.
4.
Press Enter.
+
The
system
responds,
and the terminal
displays:
DK CONNECT
> CODE
5.
Type
the four-digit
security
code,
and press
Enter.
+
The
system
responds,
and the terminal
displays:
OK
MODE
Note:
The security
code can be entered
any time
the CODE prompt appears.
6.
Go to Section 13.7-Selecting
a Mode.
13.6
Remote Terminal Operation
13.6.1
Requirements
Terminal:
The terminal
must
interface
with
an
asynchronous
modem, communicate
in ASCII code at
300 - 9600 bps (depending
on the TTY port used),
have a standard typewriter-type
keyboard,
and display
'data via a CRT display or printer. A personal computer
capable
of emulating
the described
terminal may also
be used
(see
Figures
13-2,
13-3,
or 13-4
and
Paragraph
13-l 5).
Modem:
The
modem
must
be
full-duplex
asynchronous,
operate
at 300 - 2400 bps, and have
an RS-232 interface to connect with a terminal or PC
(as described
in the previous
paragraph).
It must
interface
with the public telephone
network
and be
compatible
with Bell 103 or 212 modem specifications.
13.6.2
Set-up
Refer to Figures 13-2, 13-3, or 13-4 and verify that the
remote terminal is connected
and set-up as follows:
1.
2.
3.
4.
5.
Connect
the terminal
and modem
together
with
the RS-232 cable.
Note:
If a personal
computer
is being used, connect
the cable to the serial "COM" port.
Connect
the modem
line input to a CO/PBX line
for access to the public telephone
network.
Set the terminal and modem bps rate to match the
PIOU(S), RSSU, RSIU, or RSIS setting.
Set the terminal
and modem
for "Full Duplex"
operation.
Set the terminal parameters
to:
Word length: 7 bits
Stop bits: 1
Parity: Even
13.6.3
Remote
Operation
Automatic
connection
via ringing
assignments:
To
establish communication
between
the remote terminal
and the RMDS or IMDU, call the number of the system
CO line assigned
to ring the RMDS or IMDU via the
remote terminal/modem
set-up:
1.
Observe the following:
+
When the CO line rings-in,
it will connect
to
the RMDS or IMDU and the RMDS or IMDU
will respond
by returning
modem tone to the
remote modem.
+
The remote modem will return modem tone to
the RMDS or IMDU and communication
will
be established.
+
When
communication
is established,
the
terminal
will
display:
CONNECTED
or
COMMUNICATIONS
(see
Note
in the
following section).
2.
To continue,
enter
the security
code
per the
following section.