Local Terminal Operation; Requirements - Toshiba Strata DK 280 Installation Manual

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Note:
The security codes are initialized as "0000".
These codes can also be changed
via a local
or remote terminal.
13.4.5
IMDU
and
RMDS
On-site
Testing
From any working
station, test the functioning
of the
RMDS or IMDU.
1.
Press an Intercom
or [DN]
button.
Receive
intercom dial tone.
2.
Dial # 1 9. Receive modem tone from the IMDU
or RMDS after a two-second
delay.
Notes:
If you do not receive modem tone:
1. Check to see that the SW3 switch on the
PIOU/PIOUS
is set to "MODEM".
See
Chapter 4-Printed
Circuit Boards.
2.
Check
Program
77-1,
LED
14 for
IMDU/RMDS
assignment.
3.
Check Program 03 for the correct RSIU or
PIOU/PIOUS/RSSU
slot assignment.
4.
Check Program 76 for RSIU or RSIS TTY
assignment.
3.
Press the Spkr
button to release.
4.
Make an incoming
call over each CO line that is
programmed
to ring the RMDS or IMDU (station
#19).
Receive
modem
tone from the RMDS or IMDU
after a two-second
delay with each call.
Note:
This test checks
basic programming
and
RMDS or IMDU operation,
and should
be
completed
before
continuing
with Remote
Administration
and Maintenance
installation.
5.
If a terminal
is to be used
on-site,
refer
to
Paragraph
13-5. For off-site programming
refer to
Paragraph
13-6.
Conventions
for Local
and
Remote
Terminal Operation
Delete
=
the Delete key
Enter
=
the Enter or Return key
Spacebar
=
the space bar
J
13.5
Local Terminal ,Operation
13.5.1
Requirements
The KSU must have an RSIU, RSIS, RSSU, PIOU, or
PIOUS PC6 installed
per Chapter
4-Printed
Circuit
Boards. Refer to Paragraph
13-4 and Figure 13-5 for
terminal installation
details.
The local terminal must have an EIA RS-232 interface,
communicate
in ASCII
code
(seven-bit
word
length/one
stop bit/even
parity) at 300 - 9600 bps,
have a standard typewriter-type
keyboard,
and display
data via a CRT display or printer. A personal computer
capable of emulating
the described
terminal
may also
be used (see Figure 13-5).
Operating
the terminals,
local or remote,
is identi?al.
The only difference
is the physical connection
and the
method used to establish initial communications.
13.5.2
Set-up
Refer to Figure 13-2 and verify that the local terminal
is connected
and set up as follows:
1.
Connect
the
RS-232
cable
to the
terminal
connector and the RSIU, RSIS, RSSU, or PIOU(S)
TTY connector
(Figure 13-5).
Note:
If a personal computer is being used, connect
the cable to the serial "COM" port.
2.
Set the terminal
baud rate to match the PIOU or
PIOUS
SW2
setting
(300
or 1200
bps with
PIOU/PIOUS/RSSU
or j200-9600
bps with RSIU
or RSIS).
3.
Set the terminal for "Full Duplex" operation.
4.
Set the keyboard for
Caps
Lock
on.