Performing A Hot Start; Resetting The System; Initial Programming - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
System Hardware Manual
4.
Continue holding the Load button for approximately three
seconds or until LED 2 starts flashing red.
5.
Release the Load button.
6.
When the system has completed reloading the software (two
minutes), the Status LED is flashing on the CD-CP00.
2.6.2

Performing a Hot Start

The section describes how to load system software from flash
memory and customer data from RAM memory.
System software is loaded from flash memory, and the
customer data is loaded from RAM memory.
1.
Turn the system power off.
2.
After it has powered down, press the button again to power the
system back up. Wait approximately two minutes.
3.
When the system has completed reloading the software, the
Status LED is flashing on the CD-CP00.
2.6.3

Resetting the System

This section describes resetting a system that is running. Observe
the important information listed below.
To reset the system:
2.6.3.1

Initial Programming

The system can be programmed using three methods:
To program using a multiline terminal, enter programming
mode:
1. Go to any working display telephone.
2. Do not lift the handset.
3. Press Speaker.
IMPORTANT CONSIDERATIONS
Programming using a multiline terminal
PC Programming
Web Programming
In a newly installed system, use extension (port 1).
Issue 9.0
4 - 9

Advertisement

Table of Contents
loading