External Paging; External Page; Installing An External; Section 5 External Paging - NEC Univerge SV8100 System Hardware Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
E
S
5
XTERNAL
ECTION
5.1
5.2
System Hardware Manual
P
AGING

External Page

Two external page zone/door box circuits are provided by each PGD Adapter
installed. Each Door Box/external page circuit provides a dry relay contact.
The CD-CP00 also provides a connection for external paging and a relay. The
external page on the CD-CP00 is speaker number 9 – the relay is number 0.
The external page speakers provided by the PGD Adapters are 1~8 – the
relays on the PGD Adapters are numbered 1~8.
The PGD Adapter can be used for talkback with External Page, as can a CO
trunk port with the proper external page equipment (ex: Valcom) – set
Program 31-06-03 to 0 for talkback. However, the external page circuit on the
CD-CP00 cannot be used for talkback.
A PGD Adapter circuit used for External Paging cannot
be used for an analogue Door Box.
Installing an External Page System
1.
Connecting to the CD-CP00:
Connect an RCA line from the CN8 or CN9 connector on the CD-CP00
to the appropriate location on the extension cross-connect block.
2.
Connect the two-conductor station cable from the cross-connect block to
the external relay/external page.
3.
Install bridging clips as required.
OR
1.
Connecting to the PGD Adapter:
Make sure the jumper in the PGD Adapter for the channel is set
correctly. (Refer to
7-4).
2.
If a line cord was not previously connected to the PGD Adapter,
complete Steps 3-6. Otherwise, skip to Step 7.
3.
Install a modular jack for each PGD Adapter. For each module, run one-
pair 24 AWG station cable from the cross-connect block to a modular
jack. Ground the unused pair.
Figure 7-4 PGD Adapter Jumper Settings on page