UNIVERGE SV8100
System Hardware Manual
The CD-4LCA and CD-8LCA are not rated for OPX use. A
CD-4DIOPB blade should be used instead (it supports the analogue
DID and single line telephone interface functions, such as
Off-Premise Extensions).
One extension status LED
One blade status LEDs
Constant current type battery feeding (25mA / -28Vdc)
Feeding Polarity Reverse Ability
Connector for PZ-4LCA/PZ-8LCE Daughter Board
Ring Generator
Caller ID Sending Ability
Message Wait Lamp Ability
The CD-8LCA consumes eight ports ranging between ports
001~512. The CN3 and CN5 connectors each provide connection to
four analogue station ports. The CNx connectors are not polarity
sensitive.
Refer to the following table for maximum upgrade capacities of the
CD-4LCA
CD-8LCA blades:
/
Table 2-4 SV8100 Maximum 9.5" Gateway and 19" System Capacities
– Blades on page 2-9
4.3.2

Installation

Install the CD-4LCA/ CD-8LCA blade in any available universal slot.
If the PZ-4LCA/PZ-8LCE is used, install it prior to inserting the CD-8LCA
into the chassis.
When connecting a fax machine or analogue
modem, make sure to set Program 15-03-03 to 1
(special terminal) to avoid communication
problems.
The CD-4LCA/CD-8LCA blade and the
PZ-4LCA/PZ-8LCE daughter board are
categorized as TNV2. With this designation,
off-premise wiring is not acceptable. Any cabling
to these blades or daughter boards must be in the
building – no outside cabling is permitted.
Branch connection is not acceptable.
Issue 9.0
4 - 61