Program
Number
80-04-02
80-04-03
80-04-04
80-04-05
Automatic Release
Program Name
Call Progress Tone Detector
Setup – Min. Detection Level
Call Progress Tone Detector
Setup – S/N Ratio
Call Progress Tone Detector
Setup – No Tone Time
Call Progress Tone Detector
Setup – Pulse Count
Description/Comments
Use this option to set the minimum
detection level.
Use this option to set the Signal to
Noise ratio.
Use this option to set No Tone
Time.
Use this option to set the Pulse
Count.
Issue 5.0
Assigned Data
0~15
detect level 0:
–15dBm(0) to
–30dBm(15)
detect level 1:
–30dBm(0) to
–45dBm(15)
detect level 2:
–40dBm(0) to
–55dBm(15)
default:
Type 1 (DT) – 15
(-25dBm)
Type 2 (BT) – 15
(-25dBm)
Type 3 (RBT) – 15
(-25dBm)
Type 4, Type 5 – 0
0~4 (0dB ~ -20dB)
Default:
Type 1 (DT) = 4
(-20dB)
Type 2 (BT) = 4
(-20dB)
Type 3 (RBT) = 4
(-20dB)
Type 4 = 0
Type 5 = 0
0~255 (30+30-
7680ms)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
1~255
default:
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 – 0
1 - 93